Contact us: +39 02 89 101 42 – Contacts
0,00 €
Series ES291 transducers have a built-in monocrystalline silicium MEMS sensor for measuring inclination (with absolute vertical reference) as well as acceleration on X and Y axis.
MEMS sensors can measure both static and dynamic accelerations therefore they can as well as be used to measure inclinations that are typically static accelerations.
MEMS sensor measure acceleration and tilt by means of a differential capacitor whose parts move when a difference of acceleration and tilt is applied.
MEMS sensors are extremely rugged and can withstand hi shocks and vibrations with also the advantage of being miniaturized and with a good price to performance ratio.
Series ES291 allows to measure, accurately and with high resolution, accelerations and inclinations on X and Y axis, with absolute vertical reference.
When X and Y measuring axis are parallel to horizon, then MEMS sensor has the highest sensitivity to inclination because the working function is sinusoidal: Pitch (degrees)= sin (acceleration/1g).
When X and Y measuring axis are orthogonal to the horizon, then MEMS sensor has the lowest sensitivity to inclination because the working function is co sinusoidal: Roll (degrees)= cosine (acceleration/1g).
Applications:
Attitude control on industrial machinery, on industrial vehicles (agriculture machines, forest and timber machines, grading machines, caterpillars, drilling machines, concrete machines etc.), on boats, civil engineering applications (on dams, bridges, masonry walls, historical buildings, etc.), geotechnical applications, on antenna, inertial platforms etc.
Fullscale | |
---|---|
Sensitivity | |
Relative accuracy | ±0,1° from 0° to 30° ±0,25° from 30° to 45° |
Crossed sensitivity | 2% FS for each axis |
Power supply | 24 Vdc (-20/+10%) with protection from polarity inversion and galvanic isolation (500V) |
Shock resistance | 3500g on axis XYZ |
Update rate | 50 Hz max, with the possibility to set specific filterings for each application |
Operating temperature | |
Maximum drift due to temperature | 0,4° (global) |
Environmental protection | |
Output signal type | |
Digital output | |
Material | |
Fullscale | ±180°, as rotation on vertical surface (single measuring axis) |
Model ES270 with analog outputs:• Voltage output:Biaxial X-Y measuring axis: each measuring axis has a 0 to +5V output, calibrated as follows: 0V=-FS°, +2,5V=0°, +5V=+FS°• Current output:Y or Y single measuring axis with 4-20mA 2 wires output, calibrated as follows: 4mA=-FS°, 12mA=0°, 20mA=+FS° Electrical connection: 2m long shielded cable (no connector option is available).Resolution: 1mVrms =0,06° =1milliG (not including application mechanical/electrical noise).Zero signal asymmetry: 4% FS.Bandwidth: 10 Hz (under request for quantity order: 1-50-100-200-500 Hz). Model ES270 with digital outputs:Biaxial X and Y measuring axis with digital data transmission: RS485 Modbus, CAN Open DS406 profile, Profibus DP. Digitally transmitted values: X-Y tilt (degrees, decimal, radiants, mm/m), peak inclination, X-Y acceleration, peak acceleration, Z rotation, temperature (°C, °K, °F), peak temperature.Electrical connection: 2m long shielded cable with gland or by means of M12 connector.Resolution: 0,025° = 0,244millig (not including application mechanical/electrical noise).ES270 with digital outputs does not require to have a measuring range for it measures from 0 up to ±90 and from 0 up to 1700milliG.Bandwidth: up to 2,7 KHz (peak value).
Model ES270 with analog outputs:• Voltage output:Biaxial X-Y measuring axis: each measuring axis has a 0 to +5V output, calibrated as follows: 0V=-FS°, +2,5V=0°, +5V=+FS°• Current output:Y or Y single measuring axis with 4-20mA 2 wires output, calibrated as follows: 4mA=-FS°, 12mA=0°, 20mA=+FS° Electrical connection: 2m long shielded cable (no connector option is available).Resolution: 1mVrms =0,06° =1milliG (not including application mechanical/electrical noise).Zero signal asymmetry: 4% FS.Bandwidth: 10 Hz (under request for quantity order: 1-50-100-200-500 Hz).Model ES270 with digital outputs:Biaxial X and Y measuring axis with digital data transmission: RS485 Modbus, CAN Open DS406 profile, Profibus DP. Digitally transmitted values: X-Y tilt (degrees, decimal, radiants, mm/m), peak inclination, X-Y acceleration, peak acceleration, Z rotation, temperature (°C, °K, °F), peak temperature.Electrical connection: 2m long shielded cable with gland or by means of M12 connector.Resolution: 0,025° = 0,244millig (not including application mechanical/electrical noise).ES270 with digital outputs does not require to have a measuring range for it measures from 0 up to ±90 and from 0 up to 1700milliG.Bandwidth: up to 2,7 KHz (peak value).