The new transducers of the PCSS series for measuring displacement or level are rugged, accurate, without any mechanical wear among the parts, resistant to blows and vibrations and equipped with protection against hostile environments.
It is possible to measure linear displacements, using a magnetic ring cursor, or fluid level, by means of a magnetic float.
The level / linear position transducers of the PCSS series are rugged, accurate, without mechanical wear between the measuring probe and the float, they are resistant to shock and vibrations and are equipped with protection against hostile environments.
They are absolute measure transducers – of a magnetostrictive type – with measuring ranges from 100 to 3,000 mm, which measure the position of the magnetic float compared to the probe in a fluid digitally and continuously with no friction or wear between the parts. The measuring probe, that is 10 mm in diameter, is made of AISI316L stainless steel with TIG welding, in order to make it possible to be used in the most severe operating conditions, in pharmaceutical, food or chemical applications, with working pressures in the area of 350 bar and peaks up to 700 bar.
The transducer is fixed to the tank by means of a threaded M18 x 1.5 nipple to which the measuring electronics is connected, with the possibility of a connection to the control electronics by means of a cable or connector
The position measurement is available as digital data in the calibration units – via a RS485 connection with a Modbus, or CANopen protocol – or as an analog signal (voltage or current).
The transducers of the PCSS series are CE marked, they have passed EMC tests and are also available in an explosion-proof case.
Accuracy | on transducers up to 500 mm = ± 0,06 ### on transducers from 500 to 3000 mm = ± 0,3 mm |
---|---|
Sampling frequency | Up to 200 Hz (according to the probe length) |
Supply | from 19 to 30 Vdc (±15%), with protection of polarity inversion (diodes and protection fuse) ### current <50 mA (through 5 poles shielded wire, twisted couples) |
Operating temperature | from -40° to 110°C for the measuring support###from -40° to +85° fot the electronics (Rh 95%) |
Operating pressure | 350 bar (up to 700 bar for the measuring support) |
Environmental protection | |
Fullscale | 1600 mm, 100 mm, 1000 mm, 1050 mm, 1100 mm, 1150 mm, 1200 mm, 1250 mm, 1300 mm, 1350 mm, 1400 mm, 1450 mm, 150 mm, 1500 mm, 1550 mm, 1650 mm, 1700 mm, 1750 mm, 1800 mm, 1850 mm, 1900 mm, 1950 mm, 200 mm, 2000 mm, 2050 mm, 2100 mm, 2150 mm, 2200 mm, 2250 mm, 2300 mm, 2350 mm, 2400 mm, 2450 mm, 250 mm, 2500 mm, 2550 mm, 2600 mm, 2650 mm, 2700 mm, 2750 mm, 2800 mm, 2850 mm, 2900 mm, 2950 mm, 300 mm, 3000 mm, 350 mm, 400 mm, 450 mm, 500 mm, 550 mm, 600 mm, 650 mm, 700 mm, 750 mm, 800 mm, 850 mm, 900 mm, 950 mm |
Output signal type | |
Digital output | |
Material | |
Sensitivity | |
Zero adjust range | 100% (anywhere in the active measuring area, functionality of system where the I10 electronics is installed) |
Resolution on analogue output | 16 bits (for the internal D/A converter) |
Analog output |