Catalog

PCSS level transducers

0,00 

The new transducers of the PCSS series for measuring displacement or level are rugged, accurate, without any mechanical wear among the parts, resistant to blows and vibrations and equipped with protection against hostile environments.

It is possible to measure linear displacements, using a magnetic ring cursor, or fluid level, by means of a magnetic float.

  • Length of measuring probes from 100 to 3,000 mm
  • Outputs Start Stop
  • Measuring probe diameter 10 mm in stainless steel 316L
  • Excellent quality/price ratio

Clear

The level / linear position transducers of the PCSS series are rugged, accurate, without mechanical wear between the measuring probe and the float, they are resistant to shock and vibrations and are equipped with protection against hostile environments.

They are absolute measure transducers – of a magnetostrictive type – with measuring ranges from 100 to 3,000 mm, which measure the position of the magnetic float compared to the probe in a fluid digitally and continuously with no friction or wear between the parts. The measuring probe, that is 10 mm in diameter, is made of AISI316L stainless steel with TIG welding, in order to make it possible to be used in the most severe operating conditions, in pharmaceutical, food or chemical applications, with working pressures in the area of 350 bar and peaks up to 700 bar.

The transducer is fixed to the tank by means of a threaded M18 x 1.5 nipple to which the measuring electronics is connected, with the possibility of a connection to the control electronics by means of a cable or connector

The position measurement is available as digital data in the calibration units – via a RS485 connection with a Modbus, or CANopen protocol – or as an analog signal (voltage or current).

The transducers of the PCSS series are CE marked, they have passed EMC tests and are also available in an explosion-proof case.

Accuracy

on transducers up to 500 mm = ± 0,06 ### on transducers from 500 to 3000 mm = ± 0,3 mm

Sampling frequency

Up to 200 Hz (according to the probe length)

Supply

from 19 to 30 Vdc (±15%), with protection of polarity inversion (diodes and protection fuse) ### current <50 mA (through 5 poles shielded wire, twisted couples)

Operating temperature

from -40° to 110°C for the measuring support###from -40° to +85° fot the electronics (Rh 95%)

Operating pressure

350 bar (up to 700 bar for the measuring support)

Environmental protection

Fullscale

, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Output signal type

Digital output

Material

,

Sensitivity

Zero adjust range

100% (anywhere in the active measuring area, functionality of system where the I10 electronics is installed)

Resolution on analogue output

16 bits (for the internal D/A converter)

Analog output

,

Ingombri dimensionali PCS III